Raceway/Wire Molding Capacity Guide & FAQ
Q: How much cabling can each type of raceway hold?
A:
Raceway Fill Chart
|
Raceway Width
|
|
3/4"
|
1-1/4"
|
1-3/4"
|
Wire Type
|
Size
|
Diameter
|
40%
|
Max.
|
40%
|
Max.
|
40%
|
Max.
|
Coaxial
|
RG6/U
|
0.27
|
1
|
2
|
4
|
8
|
9
|
16
|
|
RG59/U
|
0.242
|
1
|
2
|
5
|
10
|
12
|
20
|
|
RG62/U
|
0.242
|
1
|
2
|
5
|
10
|
12
|
20
|
|
RG58/U
|
0.193
|
3
|
5
|
9
|
15
|
18
|
30
|
Twisted Pair
|
2 Pair
|
0.14
|
5
|
10
|
17
|
30
|
35
|
60
|
24 AWG
|
3 Pair
|
0.15
|
4
|
8
|
15
|
25
|
31
|
50
|
Unshielded
|
4 Pair Cat5e
|
0.217
|
2
|
4
|
7
|
12
|
14
|
25
|
|
4 Pair Cat6
|
0.24
|
1
|
2
|
5
|
10
|
12
|
20
|
|
25 Pair
|
0.41
|
0
|
1
|
2
|
4
|
4
|
7
|
Fiber Optic
|
2 Strand
|
0.175
|
3
|
6
|
11
|
18
|
23
|
36
|
FA Jacket
|
4 Strand
|
0.185
|
3
|
5
|
10
|
16
|
20
|
32
|
OFNP
|
6 Strand
|
0.21
|
2
|
4
|
7
|
12
|
15
|
25
|
Electrical
|
14 AWG
|
0.105
|
|
7
|
|
10
|
|
14
|
|
12 AWG
|
0.122
|
|
5
|
|
8
|
|
11
|
|
10 AWG
|
0.153
|
|
3
|
|
5
|
|
6
|
40% - Column follows the guidelines of EIA/TIA for cable fill allowing for additions after install
Max. - Recommended maximum fill based on bend radius and internal cabling area
___
Q: In what lengths and quantities are raceway pieces available?
A: Raceway is available in 6' pieces. There is no minimum order quantity requirement, and case lots contain 20 pieces.
___
Q: How does raceway attach to surfaces?
A: Raceway features a double-sided, self-mounting adhesive backing for quick and easy mounting to any suitable surface.
___
Q: What is the best way of cutting raceway to suit my application?
A: For quick, clean and easy raceway length customizations, we recommend using our PVC & Wire Duct Cutter.
___
Q: Is it okay to paint raceway?
A: Yes, raceway can be painted any color to suit any application.
|
|
|
|